Figure 1-8.
Figure 1-8
You can refer to the following sheet and
Figure 1-8 for alarm input and output information.
In the first line, from
the left to the right,:
12345
678910
11121314
1516
ALARM 1 to ALARM 16. The alarm becomes active in low voltage.
In the first line after
the number 1-16,
from the left to the
right:
NO1 C1
NO2 C2
NO3 C3
NO4 C4,
NO5 C5 NC5
The first four are four groups of normal open activation output
(on/off button)
NO5 C5 NC5 is a group of NO/NC activation output (on/off button)
CTRL 12V
Control power output. You need to close the device power to cancel
the alarm.
+12V
It is external power input. Need the peripheral equipment to provide
+12V power (below 1A).
Earth cable.
485 A/B
485 communication port. They are used to control devices such as
PTZ. Please parallel connect 120TΩ between A/B cables if there are
too many PTZ decoders.
2U Series (HD-SDI series)
Figure 1-9
In the first line, from
the left to the right,:
1234
ALARM 1 to ALARM 4. The alarm becomes active in low voltage.
In the first line after
the number 1-4,
from the left to the
right:
NO1 C1
NO2 C2
NO3 C3
NO4 C4,
The first four are four groups of normal open activation output
(on/off button)
NO5 C5 NC5 is a group of NO/NC activation output (on/off button)
AB cable
connection